The assessment standard of fogging machines in Udonthani province in 2558
Main Article Content
Abstract
The study aimed to evaluate the performance of the fogging machine with the standards in the local administrative organizations In Udonthani Province. This is the cross-sectional study, 16 local administrative organizations were purposively selected as samplings areas. The study was performed during March to July, 2014 by standard of fogging machine.
The results were found as followings: 65 machines were selected but could be evaluated only 59 machines (90.77 %). The machine divided in 6 categories, Igeba, Best Fogger, Swing Fog, Green Fog, IZ-Fog and Plus Fog as 40,12, 3, 2, 1, 1 machines respectively. Moreover; 49 machines (83.05 %) were given the standard temperature, only 10 machines (16.95 %) were given exceeds the standardized temperature limited. Additionally, 32 machines (54.24 %) were given standardized flow rate of the chemicals particle, while 17 machines (28.81 %) were given exceeds the standardized size limited. Furthermore; 49 machines (83.05 %) were given the standardized particle volume median diameter (VMD). only 10 machines (16.95 %) were given exceeds the standardized limited.
This was the very important study, so as to know the quality of the fogging machine that they were normally used to control of dengue fever in all areas of this province.
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The opinions and content expressed in the articles are solely those of the individual authors and do not necessarily reflect the views of the journal or the authors’ affiliated institutions. Authors are fully responsible for the accuracy and correctness of their work.
Any reuse, reproduction, or redistribution of the articles, content, data, or images in other forms requires prior written permission from the Division of Vector Borne Diseases.